China Rek RK9950 Program Controlled Leakage Current Tester
Product Overview
The Programmable Leakage Current Tester Is A 5-Inch TFT LCD Display. The Tester Adopts 32-Bit High-Speed MCU And Large-Scale Digital Circuit Design,Built In GB9706.1-2007 (IEC60601-1:1998) Body Impedance Simulation Network,The Card MD Network Interface Contains MD-A (In Line With GB/T12113-2003 And GB4793.1-2007)、MD-B(Accord With GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、GB8898-2011、GB7000.1-2015)、MD-C(Accord With GB/T12113-2003、GB7000.1-2015)、MD-D(Accord With GB4793.1-2007)、MD-E(Accord With GB4943.1-2011、GB4793.1-2007)、MD-F(Accord With GB7000.1-2015)。Load Voltage And Current Overrun Protection; MD Network Multiple Fast Protection, Safe And Reliable. Dynamic And Static Power Supply Test States; Leakage Current Test Automatically Switches L (Phase Line) And N (Zero Line). Its Setting And Operation Are Very Simple, And Provides PLC Remote Control Interface, RS232C, RS485, USB And Other Interfaces, Which Is Convenient For Users To Quickly Combine Into A Comprehensive Test System.
Packing&Shipping


for reference .Then make payment as the way you like , as soon as the payment have been confirmed ,we will arrange shippment
within 3 days .
been confirmed.
| 1、Specific Parameters | |||||
| Model | RK9950(Passive) | RK9950A(500VA) | RK9950B(1000VA) | RK9950C | |
| Basic Functions | Screen Size | 5-Inch TFT LCD Screen | |||
| Number Key | Parameter Setting Digital Input | ||||
| Coding Switch | Parameter Selection And Confirmation Function | ||||
| Up, Down, Left And Right Function Keys |
Parameter Setting Up And Down Selection Function | ||||
| LOCK Keyboard Locking Function | Prevent Accidental Modification Of Test Conditions Or Prohibit Modification Of Test Conditions | ||||
| Alarm Function | Voice Alarm | ||||
| Communication Interface | RS232C、RS485、USB | ||||
| USB Interface | Copy, Copy And Storage Functions | ||||
| Control Interface | HANDLER(PLC) | ||||
| Test Method | Dynamic, Static | ||||
| Load Voltage(AC) | Range | 0-300V | |||
| Accuracy | + (2% ×Display Value +0.5V) | ||||
| Frequency | 50/60Hz | ||||
| Load Current(AC) | Maximum | 25A | |||
| Over Current Protection | Sound And Light Alarm, Cut Off The Load Output | ||||
| Leakage Current Setting | Upper Limit Setting | ||||
| Range | 0.001-20.00mA | ||||
| Resolution | <10mA,0.001/Step >10mA, 0.01mA/Step | ||||
| Lower Limit Setting | |||||
| Range | 0.000-20.00mA | ||||
| Resolution | <10mA,0.001/Step >10mA, 0.01mA/Step | ||||
| Explanation | The Lower Limit Is Set To 0 Without Judgment | ||||
| Leakage Current Measurement | Range And Accuracy | 0.001-0.050mA DC-10KHz | ± (5% × Display Value + 5 Words) | ||
| 0.050-20.00mA DC-10KHz | ± (2% × Display Value + 2 Words) | ||||
| 0.050-20.00mA 10KHz-1MHz | ± (5% × Display Value + 5 Words) | ||||
| MD Simulated Human Network | 8 Standard Networks | MD-A(GB/T12113-2003、GB4793.1-2007)、MD-B B1(GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、GB8898-2011、GB7000.1-2015)、MD-C(GB/T12113-2003、GB7000.1-2015)、MD-D(GB4793.1-2007)、MD-E(GB4943.1-2011、GB4793.1-2007)、MD-F(IEC60598-1:2014、GB4793.1-2007)、MD-G(GB4943.1-2011、IEC60950-1:2005、GB4793.1-2007、IEC61010-1:2001) | |||
| Test Time | Range | Single Timing Test: 0.1-999s ± 1%; Closing Time Is Continuous Test | |||
| Explanation | When Setting 0S Test, Only N-Wire Is Tested,No L Conversion | ||||
| Output Power | Passive | 500VA | 1000VA | Three Phase Passive | |
| External Power Supply | External Connection | Built In | Built In | External Connection | |
| 2、General Technical Index | |||||
| General Technical Index | |||||
| Working Temperature And Humidity | 0℃-40℃,≦75%RH | ||||
| Power Supply | 100V-121V,198V-242V,47.5-63Hz 5A 250V | ||||
| Fuse Size | 5A 250V 10A 110V | ||||
| External Volume(D×H×W) | 430mm×105mm×350mm | ||||
| Weight | 13KG | 16KG | 18KG | 14KG | |
| MODEL | PICTURE | TYPE | SUMMARY |
| RK995001 | ![]() |
Standard | The Instrument Is Equipped With Standard Power Cable, Which Can Be Purchased Separately. |
| RK20K | ![]() |
Standard | The Instrument Is Equipped With Standard Data Cable, Which Can Be Purchased Separately. |
| RK00001 | ![]() |
Standard | The Instrument Is Equipped With Standard Power Cord, Which Can Be Purchased Separately. |
| Certificate Warranty Card | ![]() |
Standard | Instrument Standard Certificate And Warranty Card. |
| Factory Calibration Certificate | ![]() |
Standard | Calibration Certificate Of Instrument Standard Products. |
| Instructions | ![]() |
Standard | The Operation Manual Of The Instrument Standard Product. |
| PC software | ![]() |
Optional
|
The instrument is equipped with 16g U disk (including upper computer software). |
| RS232 to USB cable | ![]() |
Optional
|
The instrument is equipped with RS232 to USB cable (upper computer).
|
| USB to square port cable | ![]() |
Optional
|
The instrument is equipped with USB square port connecting cable (upper computer).
|