Uhlelo Lokuhlola Ukuphepha Kwedivayisi Yezokwelapha

Umhloli wamanje wokuvuza kwezokwelapha olawulwa uhlelo RK7505y

Uhlelo oluphelele lokuhlola lwemithethonqubo yokuphepha yemishini kagesi yezokwelapha

Uhlelo oluphelele lokuhlola lwemithethonqubo yokuphepha yemishini kagesi yezokwelapha

Imishini kagesi yezokwelapha, njengomkhiqizo okhethekile embonini kagesi, idinga ukuhlolwa okufanele kokuphepha kukagesi.Ngokuvamile, izinto zikagesi zezokwelapha ezihilelekile zihlanganisa izithombe (imishini ye-X-ray, izikena ze-CT, i-magnetic resonance, i-B-ultrasound), abahlaziyi bezokwelapha, kanye nemishini yokwelapha nge-laser, imishini yokubulala izinzwa, ama-ventilator, ukujikeleza kwe-extracorporeal namanye amathuluzi ezokwelapha ahlobene.Ucwaningo nokuthuthukiswa komkhiqizo wedivayisi yezokwelapha Ukuhlolwa kokuphepha kukagesi okuhlosiwe nokunye ukuhlola okuhlobene kuyadingeka ngesikhathi sokukhiqiza.

I-GB9706.1-2020 Imishini Kagesi Yezokwelapha

I-GB9706.1-2007/IEC6060 1-1-1988 Imishini Kagesi Yezokwelapha

I-UL260 1-2002 Imishini Kagesi Yezokwelapha

UL544-1988 Izisetshenziswa Zezokwelapha Zamazinyo

Izindinganiso zikagesi zezokwelapha zikazwelonke

Uhlelo Lokuhlola Ukuphepha Kwedivayisi Yezokwelapha

1. Izimfuneko zamazinga okuhlola ukuphepha kumishini yezokwelapha

Imithetho yamazwe ngamazwe GB9706 1 (IEC6060-1) "Impahla kagesi yezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha" kanye ne-GB4793 1 (IEC6060-1) "Izimfuneko zokuphepha zamathuluzi kagesi okulinganisa, ukulawula nokusebenzisa ilabhorethri - Ingxenye 1: Izidingo ezijwayelekile"

2. Ukuhumusha okujwayelekile

1. GB9706 1 (IEC6060-1) "Impahla kagesi yezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha" ibeka ukuthi i-voltage engeqi ingxenye yenani elishiwo kufanele isetshenziswe ekuqaleni, bese i-voltage inyuswe ifinyelele kuleyo eshiwo. inani phakathi kwamasekhondi angu-10.Leli nani kufanele ligcinwe ngomzuzu ongu-1, bese i-voltage kufanele yehliswe ibe ngaphansi kwengxenye yenani elishiwo phakathi nemizuzwana eyi-10.I-voltage waveform ethile imi kanje:

I-voltage waveform

2. GB9706 1 (IEC6060-1) "Impahla kagesi yezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha" ibeka ukuthi i-flashover noma ukuphuka akufanele kwenzeke ngesikhathi sokuhlolwa.Abahloli bamandla kagesi abavamile bangathola kuphela iphutha "lokuhlukana" kwempahla ehloliwe.Uma kukhona i-flashover ngaphakathi kwemishini kagesi ehloliwe, ukuvuza kwamanje kuncane kakhulu futhi akukho msindo ocacile nokukhanya, okwenza kube nzima ukunquma.Ngakho-ke, ukumelana nengcindezi yezokwelapha kungeze isikhombimsebenzisi se-oscilloscope ukuze kubonwe isenzakalo se-flashover ngomdwebo we-Li Shayu.

1484e936add89e21e77725dc803c8f0
I-RK7505

Isikhathi sokuthumela: Dec-04-2023
  • facebook
  • linkedin
  • youtube
  • i-twitter
  • blogger
Imikhiqizo efakiwe, Imephu yesayithi, I-Digital High Voltage Meter, I-High Static Voltage Meter, I-High-Voltage Digital Meter, High Voltage Calibration Meter, Imitha ye-Voltage, High Voltage Meter, Yonke Imikhiqizo

Thumela umlayezo wakho kithi:

Bhala umyalezo wakho lapha futhi usithumelele wona