Products
-
China Rek RK2810A/RK2810B/RK2811D digital bridge
RK2810A measurement function
Measurement parameters: Main: L/C/R/Z Sub: D/Q/θ/ESR
Basic accuracy: 0.20%
Equivalent circuit: series, parallel
Deviation methods: 1%, 5%, 10%, 20%
Range mode: automatic
RK2810B measurement function
Measurement parameters: Main: Z/Y/L/C/R/G Sub: D/Q/X/B/θ r/θ d/r
Basic accuracy: 0.10%
Equivalent circuit: series, parallel
Deviation method: 0.1%/0.2%/0.25%/0.35%/0.65%/1%
Range mode: automatic, hold
RK2811D measurement function
Measurement parameters: Main: L/C/R/Z Sub: D/Q/θ/X/ESR
Basic accuracy: 0.20%
Equivalent circuit: series, parallel
Deviation methods: 1%, 5%, 10%, 20%
Range mode: automatic, hold -
RK1312-20 Audio Swept Frequency Signal Generator
Frequency range: 20 Hz to 20 kHz
Resolution: 1 Hz
Output voltage accuracy: ±(1% + 3 digits)
Distortion: ≤0.8% -
RKP6000/RKP6001/RKP6002/RKP6003/RKP6005 Programmable Variable Frequency Power Supply
RKP6000
Capacity: 500VA
Maximum current: L=150.0V: 4.2A H=300V: 2.1A
RKP6001
Capacity: 1kVA
Maximum current: L=150.0V: 8.4A H=300V: 4.2A
RKP6002
Capacity: 2kVA
Maximum current: L=150.0V: 16.66A H=300V: 8.3A
RKP6003
Capacity: 3kVA
Maximum current: L=150.0V: 25A H=300V: 12.5A
RKP6005
Capacity: 5kVA
Maximum current: L=150.0V: 41.66A H=300V: 20.83A -
China Rek RK2830/RK2837/RK2837A Digital Bridge
RK2830
Measurement parameters: | Z |, C,L,R, X, ESR,D,Q,θ
Test frequency: 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz
Test level: 50mV-2.0V, resolution: 10mV
RK2837
Measurement parameters: | Z |, C,L,R, X, |Y|,B,G,ESR,D,Q,θ
Test frequency: 50Hz-100kHz, 10mHz step
Test level: 10mV-1.0V, resolution: 10mV
RK2837A
Measurement parameters: | Z |, C,L,R, X, |Y|,B,G,D,Q,θ
Test frequency: 50Hz-200kHz, resolution: 10mHz
Test level: 10mV-2.0V, resolution: 10mV -
China Rek RK4008/RK4016/RK4008X/RK4016X Multi channel Temperature Inspection Instrument
RK4008:
Number of channels: 8 channels
Compatible thermocouples: K, S, R, N, E, J, T, B
RK4016:
Number of channels: 16 channels
Compatible thermocouples: K, S, R, N, E, J, T, BRK4008X:
Number of channels: 8 channels
Sampling speed: 0.3S per channel
Operation method: Touchscreen
Standard thermocouple: Type K thermocouple
Compatible thermocouples: K, S, R, N, E, J, T, B
RK4016X:
Channel count: 16 channels
Sampling speed: 0.3S per channel
Operation method: Touchscreen
Standard thermocouple: Type K thermocouple
Compatible thermocouples: K, S, R, N, E, J, T, B -
China Rek RK9975-10/RK9975-10A/RK9975-10B Programmable Ultra High Voltage Tester
RK9975-10:
AC
Output voltage: (0.10-10.00) kV
Output power: 1000VA (10.0kV 100mA)
DC
Output voltage: (0.10-10.00) kV
Output power: 500VA (10.0kV 50mA)
IR (Customized Function)
Output voltage: 0.10KV-5.0KV
Test accuracy: ± (3%+5 words)
RK9975-10A:
AC
Output voltage: (0.10-10.00) kV
Output power: 1000VA (10.0kV 100mA)
DC
Output voltage: (0.10-10.00) kV
Output power: 500VA (10.0kV 50mA)
RK9975-10B:
AC
Output voltage: (0.10-10.00) kV
Output power: 1000VA (10.0kV 100mA) -
China Rek RK2678YM Medical Grounding Resistance Tester
(10.0-199.9)MΩ/(200-500)MΩ AC:5~30A ±5% 1000VA -
China Rek RK2675YM/China Rek RK2675YM-1/RK2675YM-2/RK2675YM-3/RK2675YM-5 series medical leakage current tester
Output voltage range: 0-300V Test current: AC/DC: 0-200uA AC/DC: 0.2-2mA AC: 2-10mA Test accuracy: ± 5%+3 words Test time: 0-99S (continuously adjustable)
-
China Rek RK7505YJ/RK7510YJ/RK7520YJ/RK7530YJ/RK7550YJ Programmable Medical Leakage Current Tester
Output voltage range: 0V~300V resolution 1V Accuracy: ± (5%+2 words) Output voltage capacity
RK7505YJ:500VA
RK7510YJ:1000VA
RK7520YJ:2000VA
RK7530YJ:3000VA
RK7550YJ:5000VA
-
China Rek RK7305Y Medical Ground Bond Tester
Rk7305 grounding resistance tester is used to measure the grounding resistance inside electrical equipment.
Output voltage: 6Vac MAX
Output frequency: 50Hz / 60Hz optional
Output current: 3-32Aac constant current source
-
China Rek RK9931A/RK9931B/RK9931C Programmable DC Grounding Resistance Tester
RK9931A
Current range: DC (3-40) A
Voltage range: DC 8V Max open circuit voltage
RK9931B
Current range: DC (3-60) A
Voltage range: DC 12V Max open circuit voltage
RK9931C
Current range: DC (3-100) A
Voltage range: DC 12V Max open circuit voltage -
RK2885-2/RK2885-4/RK2885-X Pulse Coil Tester
RK2885-2
Number of high-voltage channels: 2
Pulse voltage: 100V~5000V, 10V step, 5% ± 10V
Pulse energy: maximum 0.25 joules
Measurement speed: maximum 12 times/second for single winding test, maximum 2 times/second for four winding test
RK2885-4
Number of high-voltage channels: 4
Pulse voltage: 100V~5000V, 10V step, 5% ± 10V
Pulse energy: maximum 0.25 joules
Measurement speed: maximum 12 times/second for single winding test, maximum 2 times/second for four winding test -
RK8520C Programmable DC Electronic Load
Load voltage 150V
Load current 60A
Load power 300W -
China Rek RK1940-2/ RK1940-3/ RK1940-4/ RK1940-5 High Voltage Digital Meter
AC/DC:1000V ~20/30/40/50kV 1000MΩ
-
-
China Rek RK7305 Ground Bond Tester
The RK7305 grounding resistance tester is used to measure the grounding resistance inside the electrical equipment.
Output voltage: 6Vac MAX
Output frequency: 50Hz / 60Hz optional
Output current: 3-30Aac constant current source
-
China Rek RK2517/RK2517A/RK2517AN DC Resistance Tester
RK2517
Test resistance range: 1u Ω -200M Ω
Test accuracy: 0.05%+2 words (slow speed)
0.05%+5 words (medium speed)
0.5%+5 words (fast)
RK2517A
Test resistance range: 1u Ω -20M Ω
Test accuracy: 0.05%+2 words (slow speed)
0.05%+5 words (medium speed)
0.5%+5 words (fast)
RK2517AN
Test resistance range: 1u Ω -200K Ω
Test accuracy: 0.05%+2 words (slow speed)
0.05%+5 words (medium speed)
0.5%+5 words (fast) -
China Rek RK9960/ RK9960A/RK9960T Program Controlled Safety Tester
AC:0.050-5.000 DC:0.050-6.000KV
AC:0.001mA-20mA DC:0.1uA-10mA / AC:0.001mA-10mA DC:0.1uA-5mA
-
China Rek RK9310/RK9320/RK9320A/RK9320B/RK9320S/RK9330 series programmable AC/DC insulation withstand voltage tester
RK9320A
Voltage withstand range: AC: 0.050kV~5.000kV/DC: 0.050kV~6.000kV
Maximum output power: 100VA (5.000kV/20mA)
RK9320B
Voltage withstand range: AC: 0.050kV~5.000kV
Maximum output power: 100VA (5.000kV/20mA)
RK9310
Voltage withstand range: AC: 0.050kV~5.000kV/DC: 0.050kV~6.000kV
Maximum output power: 50VA (5.000kV/10mA)
Insulation resistance output voltage setting: 0.050kV~5.000kV
RK9320
Voltage withstand range: AC: 0.050kV~5.000kV/DC: 0.050kV~6.000kV
Maximum output power: 150VA (5.000kV/30mA)
Insulation resistance output voltage setting: 0.050kV~5.000kV -