RK9950 Program Controlled Leakage Current Tester


Description

Parameter

Accessories

RK2671AM/ RK2671BM/ RK2671CM Withstand Voltage Tester

Product Introduction

The RK2671AM Withstand Voltage Tester Of Meiruike Is The Measurement Instrument For  Compressive Strength,It Mainly Used For Insulation Leakage Safety Test Of Product.It Can Test The Electrical Safety Performance Index Of Breakdown Voltage,Current Of Which All Kind Of The Measured Object Intuitive,Accurate And Fast,And Can Be Used For Testing The Components And Overall Performance As A High Voltage Source.

This Series Of Tester According To The Following Standards:Standard For Household Electrical Appliances(IEC6035,GB4706.1-2001, GB4706.1-1998),Standard For Lamp(IEC60598-1-1999, GB7000.1-2000),Standard For Information (GB8898-2001,GB12113.GB4943-2001, IEC60065,IEC60950) And So On.

Application Area

Components:diode,Triode,High-Voltage Silicon Stack,All Kinds Of Electronic Transformer, Connector Assembly,High Voltage Electrical Equipment.
Household Electric Appliances:TV,Refrigerator,Air Conditioner,Washing Machine,Dryer, Electric Blanket,Charger Etc.
Insulation Material:heat Shrinkable Tube,Capacitor Film,High Pressure Tube,Insulating Paper,Insulated Shoes,Rubber Insulating Gloves,PCB Circuit Board Etc.
Instruments And Meters:oscilloscope,Signal Generator,DC Power Supply,Switching Power Supply And Other Types Of Machine.
Lighting Appliances:ballast,Road Lights,Stage Lights,Portable Lamps And Other Types Of Lamps.
Electric Heating Appliances:electric Drill,Pistol Drill,Cutting Machine,Grinding Machine,Electric Welding Machine Etc.
Wire And Cable:high Voltage Cable,Optical Cable,Electric Cable,Silicone Rubber Cable, Etc.

Performance Characteristics

AC/DC Voltage 10kV Universal Withstand Voltage Tester.
The Output Voltage Regulated Output By The Regulator,Which Has High Reliability And High Durability.
Using High Brightness LED Digital Displaying Test Time,Voltage,Current,It Can Display The Breakdown Current Value And Voltage Value In Real Time.
Alarm Current Value Can Be Preset Arbitrarily.
Test Time Using Three Digital Tube Display
Equipped With PLC Signal Input,Output Interface,It Can Constitute Easily Integrated Test System With PLC Expediently.(Optional)


  • Previous:
  • Next:

  • 1、Specific Parameters
    Model RK9950(Passive) RK9950A(500VA) RK9950B(1000VA) RK9950C
    Basic Functions Screen Size 5-Inch TFT LCD Screen
    Number Key Parameter Setting Digital Input
    Coding Switch Parameter Selection And Confirmation Function
    Up, Down, Left And Right
    Function Keys
    Parameter Setting Up And Down Selection Function
    LOCK Keyboard Locking Function Prevent Accidental Modification Of Test Conditions Or Prohibit Modification Of Test Conditions
    Alarm Function Voice Alarm
    Communication Interface RS232C、RS485、USB
    USB Interface Copy, Copy And Storage Functions
    Control Interface HANDLER(PLC)
    Test Method Dynamic, Static
    Load Voltage(AC) Range 0-300V
    Accuracy + (2% ×Display Value +0.5V)
    Frequency 50/60Hz
    Load Current(AC) Maximum 25A
    Over Current Protection Sound And Light Alarm, Cut Off The Load Output
    Leakage Current Setting Upper Limit Setting
    Range 0.001-20.00mA
    Resolution <10mA,0.001/Step    >10mA, 0.01mA/Step
    Lower Limit Setting
    Range 0.000-20.00mA
    Resolution <10mA,0.001/Step    >10mA, 0.01mA/Step
    Explanation The Lower Limit Is Set To 0 Without Judgment
    Leakage Current Measurement Range And Accuracy 0.001-0.050mA    DC-10KHz ± (5% × Display Value + 5 Words)
    0.050-20.00mA    DC-10KHz ± (2% × Display Value + 2 Words)
    0.050-20.00mA    10KHz-1MHz ± (5% × Display Value + 5 Words)
    MD Simulated Human Network 8 Standard Networks MD-A(GB/T12113-2003、GB4793.1-2007)、MD-B B1(GB/T12113-2003、GB4793.1-2007、GB4706.1-2005、GB4943.1-2011、GB8898-2011、GB7000.1-2015)、MD-C(GB/T12113-2003、GB7000.1-2015)、MD-D(GB4793.1-2007)、MD-E(GB4943.1-2011、GB4793.1-2007)、MD-F(IEC60598-1:2014、GB4793.1-2007)、MD-G(GB4943.1-2011、IEC60950-1:2005、GB4793.1-2007、IEC61010-1:2001)
    Test Time Range Single Timing Test: 0.1-999s ± 1%; Closing Time Is Continuous Test
    Explanation When Setting 0S Test, Only N-Wire Is Tested,No L Conversion
    Output Power Passive 500VA 1000VA Three Phase Passive
    External Power Supply External Connection Built In Built In External Connection
    2、General Technical Index
    General Technical Index
    Working Temperature And Humidity 0℃-40℃,≦75%RH
    Power Supply 100V-121V,198V-242V,47.5-63Hz     5A 250V
    Fuse Size  5A 250V           10A 110V
    External Volume(D×H×W) 430mm×105mm×350mm
    Weight 13KG 16KG 18KG 14KG
    MODEL PICTURE TYPE SUMMARY
    RK995001 Standard The Instrument Is Equipped With Standard Power Cable, Which Can Be Purchased Separately.
    RK20K Standard The Instrument Is Equipped With Standard Data Cable, Which Can Be Purchased Separately.
    RK00001 Standard The Instrument Is Equipped With Standard Power Cord, Which Can Be Purchased Separately.
    Certificate Warranty Card Standard Instrument Standard Certificate And Warranty Card.
    Factory Calibration Certificate Standard Calibration Certificate Of Instrument Standard Products.
    Instructions Standard The Operation Manual Of The Instrument Standard Product.